Modular Bands and Teeth

The line, the surface type and the drive tooth are selected together. This section includes 12,7; 25,4; 31,75; 38,1; 50,8 and 50,81 catalog families, cartridges and transition parts.
Modular Bands and Teeth to be taken into account
The transparency ratio of the transport surface with the modular band width is separate information. Technical names such as C, P18, P30, P45, P60, CD and R24 distinguish the model family. Similar modules, the maffian layout and the driving geometry are not used together without verification. Only the line equality in the turn tape is not sufficient; the geometry on the turn side is also controlled.
In the dental selection, the number of teeth, OD, PD and B are read together. the outer diameter of OD is the source symbols of the PD line diameter; the round and square miles options for B are assessed as published in the table. If the two miles options in the source are written side by side, the one mixed size is not ordered.
Technical image and model comparison
You can click on the product card to move to the separate page of the family you choose. The technical drawing is not used for the same purpose as the product appearance. It helps to understand the structure of the visual piece; the measurable appearance is based on connection and assembly. When multiple variants are displayed on the same technical page, match the Advanced stock code in the drawing title and in the technical table.
The empty cells in the table are not filled with predictions. the measurement unit is unknown or the record that is unconform in the catalogue is described on the product page. a non-published size is not calculated by the pixel ratio of the photo. the ordered piece must be checked that the definition written on the offer is the same as the model code. Even if the family name is similar, the link layout may change.
Measurement and offer information
In your request, specify the stock code, quantity and use place of the product. If you want to change the existing piece, share a picture of both the general appearance and the connectivity points. Breadth and infinite environment length for the band; cutting and size for the profile; number of cables and movement distance for the cable channel should also be ⁇ . Explain whether a single piece or a set with its connectivity is required.
After the technical comparison is completed, the delivery scope, material, color and necessary processing details are clarified on the offer. It is unpredictable that a link piece shown in the photo is included in the delivery. The delivery scope in the source is clearly written in models that this information is found on their own product page. Uncertain accessories are considered as separate pen before ordering.
Installation and control
The surface, the direction of movement and the access to maintenance before installation are checked. Only the renewal of the piece without the cause of the failure in the old product can cause the repetition of the same problem. Application details such as the swelling in the wire, the direction gap in the band or the excess availability in the cable channel should be shared in the technical assessment. The choice of product is based on the own installation instructions.
Frequently Asked Questions
What code should I use for the offer?
Use the IM code shown on the product page. This code is Advanced Engineering stock definition; it does not replace the manufacturer name or conformity certificate.
Can I use the size in the image directly?
Use the values in the measurable drawing of your own model only. Technical data for a lack of field From the contact page Ask for a picture.
Band, tooth and carrier matching
In a modular band set, the module, the connection pime, the dentist and the carrier are assessed together. The band line must be compatible with the drive dentist's name. The mile connection of the dentist is selected according to the mile in the machine; the same connection is not accepted by the alternatives indicated by the round hole, the square hole and the side in the source. The number of dentist is determined by knowing the settlement, bandwidth and transport conditions over the mile. The necessary dentist unit is not removed from a single photo.
The elevation of the carrier is controlled together, the moving behavior of the product and the space required in turn. The use of the high carrier does not provide better transport in all cases; the turn area and the discharge of the product are also affected. The position of the carrier spots under the band determines how the load moves along the bandwidth. The transit units do a different function than the band module; the space and the product base size are studied together in the product transfer between the two carrier.
Material options are also displayed on the technical page of each family. It should not be assumed that all materials appearing in one family are also available for another family. The same approach applies to color and locked connection options. When the requested module's cutting, connection structure and delivery length are confirmed together, the right choice for the existing carrier can be made more clearly.